
Water Heater Installation, Replacement and Repair Services in Upper Thomson
Safe, compliant water heater replacement for HDBs and condos in Upper Thomson — supervised by PUB Licensed Plumber and EMA Licensed Electrician.
Homeone provide PUB certificate for the installation to ensure the storage water heater safe to use and comply with PUB, EMA, Singapore Standard SS636:2018 Code of Practice for Water Services, SS638:2018 Code of Practice for Electrical Installations and Safety Mark Regulations
Storage water heaters are a must-have for homes in Upper Thomson — from HDB flats to condos and landed houses. Watch out for warning signs like power trips, no hot water, leaks, rust, or corrosion, as these often signal a failing heater.
Engage Homeone today for PUB Licensed and safety-compliant storage water heater replacement, installation, and repair services. Our experienced team ensures every job meets regulatory standards and delivers long-lasting performance.
Number of Water Heater Installed since 2000 in Upper Thomson
HDBs Works
743
CONDOs Works
817
Upper Thomson HDBs

Successfully completed water heater installations across Upper Thomson Road, Jalan Todak & Soo Chow Walk HDB flats — each installation supervised by PUB Licensed Plumber to ensure safety, durability, and full compliance with Singapore regulations.
Upper Thomson Condos

Completed professional water heater replacements at Upper Thomson condos including Thomson Grand, Thomson Three & Lakeview Estate — each project supervised by a PUB Licensed Plumber, fully RCCB-tested, and compliant with Singapore safety standards to ensure residents enjoy safe, reliable, and long-lasting hot water solutions.
Common Water Heater Problems

Thermostat cable burnt
A burnt thermostat cable is a common electrical fault in storage water heaters. It usually occurs when the wire insulation deteriorates due to prolonged heat exposure, loose wiring connections, or electrical overloading.

Rusty Stop Cock & Fittings
Over time, the stop cock and pipe fittings connected to a water heater can suffer from rust and corrosion due to constant contact with moisture and heated water.

Leaking Water Heater tank
In older HDBs (built before 2010).

Missing the drainpipe
Storage water heater pressure relief valve missing drainpipe – a PUB safety non-compliance

RCCB tripping during shower
Caused by failing heating element.

High Water Pressure
140 PSI water pressure is in violation of SS 636:2018 – Code of Practice for Water Services, Clause 6.7. According to the standard:
In tall buildings, fittings should not be subjected to pressures greater than 35 metres head, which is approximately 50 PSI
Unsafe unlicensed installation

- An inner tank leak is one of the clearest signs that your water heater has reached the end of its service life.
-
Corrosion over time – The tank’s enamel lining has worn off, exposing the steel to rust and water damage
- High water pressure – Excessive mains pressure puts stress on the tank walls, causing cracks and leaks
- Drain Pipe Choked
- To ensure compliance and protect your family’s health, always engage a PUB Licensed Plumber for installation and replacement works.
Step by step of Storage Water Heater Installation Process
2. Connector box inspection to confirm proper working order.
3. Water heater Drain pipe inspection to ensure the drain pipe able to drain out water and no choked.
4. water heater Installation location inspection to ensure the new storage able to service and no risk of dropping.
2. Ceiling Cutting (If applicable)
3. Drain out 80% of the water in the water heater
4. Water Heater Removal and Dismantle
2. Water Heater Installation
3. To install stainless steel SS304 hot and cold water pipe for water heater
4. To install a 2.5mm cable for the water heater
5. To install a double check valve for the water heater
6. To install earth bonding for the water heater
2. Water Flow – Hot water flow are the same with cold water
2. PUB Submission
3. PUB certificate to customer within 7 working days
Why Choose Us in Upper Thomson?
Licensed, compliant and tidy work — every time.
Need a similar installation in Upper Thomson?
Water Heater Replacements in Upper Thomson
Replace an existing Joven JH56 with a new Rheem EHG 30 at Three 11 on 24 June 2024.
Three 11 (Condo)
BEFORE
The existing Joven JH56 storage water heater, installed above the ceiling, had reached the end of its service life. Age-related issues such as reduced heating efficiency and risk of leaks made a safe, compliant replacement necessary to restore reliable hot water supply.
AFTER
A new replacement Rheem EHG 30 has been professionally installed by Homeone. The works included a new stop valve, double-check valve, and drain pipe, along with proper equipotential bonding and 2.5 mm² electrical wiring for safe operation.
Every step was carried out in strict compliance with PUB and EMA requirements, ensuring long-term reliability, safety, and full protection of the manufacturer’s warranty.
454 Sin Ming Ave (HDB)
BEFORE
The existing Ariston Andris 30R water heater in this hdb unit had reached the end of its service life. Visible internal tank leakage made repairs uneconomical, requiring a complete replacement to restore safe and reliable hot water supply.
AFTER
A new Ariston Andris2 30 RS water heater has been installed. The scope of works included the installation of a new stop valve, double-check valve, drain pipe, equipotential bonding, and 2.5mm² electrical wiring. The installation is covered by a one (1) year workmanship warranty from Homeone, in addition to the manufacturer’s warranty for the unit.
Replace an existing Ariston Andris 30R with a new Ariston Andris2 30 RS on 6 Aug 2025 at 454 Sin Ming Ave.
Other Locations In Singapore
Central
South