Rheem 65SVP10S Replaced to Rheem RCY-15 at 720 Bedok Reservoir on 5 Apr 2025

PUB Certificate Applied Replacement for Rheem Vertical Tank .00

Reason for the Callout

The homeowner reported concerns about the ageing heater and requested a safe and compliant replacement after noticing signs of rust and poor drainage.

HDB

PUB Certificate Issued: Rheem 65SVP10S Replaced to Rheem RCY-15 at 720 Bedok Reservoir Road

A homeowner at 720 Bedok Reservoir Road sought help with a leaking Rheem 65VP6S. The unit was worn and lacked PUB-required safety components. We replaced it with a compact Rheem RCY-15 (15L), ensuring full compliance and issuing a PUB Certificate under licensed plumber supervision.

Before: Rheem 65SVP10S
After: Rheem RCY-15
Date Of Replacement: 21 Apr 2025
Project Location: Bedok Reservoir Road

Before Replacement:

PUB Certificate Applied Replacement for Rheem Vertical Tank .01

The existing Rheem 65SVP10S heater had served its lifespan but was no longer safely installed. Key safety fittings were missing, including the PUB-approved check valve and anti-vacuum valve. The drainpipe was not properly routed to the nearest floor trap. No previous PUB Certificate was available for the original installation, indicating it did not go through the required regulatory documentation process.

After Replacement:

PUB Certificate Applied Replacement for Rheem Vertical Tank .02

We replaced the vertical Rheem 65SVP10S with a more space-efficient Rheem RCY-15 square tank. Our PUB Licensed Plumber installed all necessary safety components, including a compliant check valve, anti-vacuum valve, and a correctly routed drainpipe to the nearest floor trap. The entire job was documented and certified, with a PUB Certificate issued to ensure compliance and traceability for the homeowner.

Inspection Findings

  • Ageing Rheem 65SVP10S with rust and poor drainage
  • Missing approved double-check valve
  • No anti-vacuum valve present
  • Drainpipe discharged improperly
  • No previous PUB Certificate for installation

Components Replaced for PUB Submission Compliance:

  • Rheem RCY-15 electric storage water heater (15L, 4-gallon)
  • PUB-approved double-check valve
  • Drainpipe routed to floor trap
  • Stainless steel pipework (≤1m)
  • Updated fittings and electrical bonding

Replacement work scope:

  • Isolated power and water supply
  • Removed old Rheem 65SVP10S unit
  • Assessed pipe routing and floor trap discharge
  • Installed new Rheem RCY-15 with brackets
  • Fitted anti-vacuum valve and check valve
  • Installed a new stop cock
  • Connected compliant drainpipe
  • Verified bonding continuity
  • Leak testing and performance checks
  • PUB Certificate issued upon completion
PUB Submission Applied Replacement for Rheem Vertical Tank

Our PUB Licensed Plumber has endorsed that the work is done in accordance with the conditions stated below:

  1. All water service installations must be in accordance with the Public Utilities (Water Supply) Regulations, Singapore Standards 636 for Water Services, and all other relevant statutory requirements.
  2. The proposed works shall not adversely affect the existing water supply reticulation system.
  3. The proposed water storage heater is installed in accordance with the specifications and requirements of the manufacturer.
  4. The installation of double-check valves is safe and effective in preventing backflow and the back-siphonage of water from the storage water heater through the heater inlet pipe, and will be safe for use.

Conclusion:

This replacement project at Bedok Reservoir Road highlights the importance of upgrading to a safer, space-efficient unit with full PUB compliance. The original installation lacked basic safety fittings and proper drainage, posing long-term risks. With the new Rheem RCY-15 and all safety measures in place, we issued a valid PUB Certificate, confirming that the job meets SS636 plumbing regulations and is safe for continued use.

Call Now ‪+65 6742 6770‬

WhatsApp ‪+65 8816 6770