Reason for the Callout
Hot water had turned yellowish brown, and the existing heater lacked mandatory safety components like double check valve, drainpipe, and bonding.
HDB
Hot Water Yellow: Ariston AN2 15 RS Replacement at 101A Bidadari Park Drive
A resident at 101A Bidadari Park Drive HDB reported a “Hot Water Yellow” issue. Our team replaced the corroded Ariston heater with a new AN2 15 RS unit, fully compliant with PUB regulations.
Before: Ariston AN2 15 RS
After: Ariston AN2 15 RS
Date Of Replacement: 24 May 2025
Project Location: Bidadari Park Drive

Before Replacement:

The old water heater showed signs of severe internal rust, and the hot water output was discoloured. There was no double check valve, drain pipe, or earth bonding, posing a hygiene and electrical hazard.
After Replacement:

We replaced the faulty heater with a new Ariston AN2 15 RS unit. New safety fittings were installed to ensure clean water delivery and safe electrical performance.
Inspection Findings 
- Corrosion on internal tank walls
- Rusty, discoloured hot water at the outlet
- No double-check valve, which can lead the water backflow.
- No electrical bonding
- Drain water is discharging improperly due to a lack of a PRV drainpipe
New Components Replacement
- Double Check Valve – Prevents backflow contamination
- Drain Pipe – Safely channels overflow water
- 2.5mm² Cable – Provides essential electrical bonding and supplies a new power supply cable for the heater.
- Earth Bonding – Ensures electrical safety
- Gate Valve – Allows shut-off for maintenance
Replacement work scope:
- Removal of the old, rusted heater
- Supply and installation of Ariston AN2 15 RS
- Double Check Valve: Prevents backflow contamination
- Drain Pipe: Ensures safe discharge from PRV
- 2.5mm Cable & Earth Bonding: Protects users from electric shock risks
- Gate Valve: Enables convenient water shutoff during servicing


Our PUB Licensed Plumber has endorsed that the work is done in accordance with the conditions stated below:
- All water service installations must be in accordance with the Public Utilities (Water Supply) Regulations, Singapore Standards 636 for Water Services, and all other relevant statutory requirements.
- The proposed works shall not adversely affect the existing water supply reticulation system.
- The proposed water storage heater is installed in accordance with the specifications and requirements of the manufacturer.
- The installation of double-check valves is safe and effective in preventing backflow and the back-siphonage of water from the storage water heater through the heater inlet pipe, and will be safe for use.
Conclusion:
This replacement was completed by a Homeone-trained technician and supervised by a PUB-licensed plumber. All installations were carried out in full compliance with PUB regulations for safety, hygiene, and water system integrity.